License number EC13001410

Parking Lot & Commercial Exterior Lighting in West Palm Beach, FL

A dark parking lot is a problem before it is an expense. Tenants notice, customers avoid it, and if somebody is hurt or a car is broken into, the first question asked is how long the lights had been out. Nassif Electric has installed, converted and repaired exterior lighting for South Florida properties since 1976: parking lots, poles, wall packs, canopies, garages and building exteriors. We are a Florida statewide licensed unlimited electrical contractor, License EC13001410, licensed, insured and bonded, with 24/7 response. Call 561-582-2600 for parking lot lighting, pole repairs or a site lighting assessment.

Commercial restaurant exterior with illuminated signage and parking lot lighting at night
Electrical lineworkers performing utility pole wiring and maintenance using a bucket truck

What We Light Outdoors

Parking lots and site lighting

Pole-mounted area lighting for lots, drive aisles and entrances. New installations, LED conversions of existing poles, additional poles where coverage is short, and the underground circuits and contactors behind them. Most of what we do here is converting metal halide or high pressure sodium fixtures to LED on existing poles, which is the fastest improvement available to most properties.

Pole repair and replacement

Damaged, leaning and corroded poles, failed fixtures, broken photocells, and the bases and anchor bolts underneath. South Florida poles fail at the base more often than at the top, and the damage is usually not visible until somebody looks.

Wall packs and building-mounted lighting

Wall packs over doors, loading docks and service areas, and LED replacements for the old units that light up the wall and the sky but not much of the ground. Modern full-cutoff wall packs put the light where it is needed and cause far fewer complaints from neighbors.

Canopy and covered area lighting

Fuel canopies, drive-through canopies, covered walkways, porte-cocheres and loading canopies. These are high-hour, high-visibility fixtures and they are usually the first thing a customer sees of a property at night.

Parking garages

Garage and structure lighting, stairwells and elevator lobbies. Garage lighting runs continuously, which makes it one of the strongest LED conversion candidates on any property, and the lighting quality has a direct effect on how safe people feel using it.

Security lighting

Perimeter lighting, lighting for the dark corners a camera cannot see into, gate and entry lighting, and motion-activated fixtures where constant light is not wanted. Security lighting works by being aimed and controlled properly, not by being brighter. A badly placed floodlight creates glare and deep shadow, which is worse than no light at all.

Storm damage and emergency repairs

After a storm: downed and leaning poles, damaged fixtures, water-damaged circuits and photocells, and the underground faults that show up a week later when something finally shorts. We assess and repair, and we document for insurance.

Converting a Lot to LED

The most common project we do, and it is worth understanding what actually happens.

Most older lots run metal halide or high pressure sodium fixtures, typically 250 to 1,000 watts each. Modern LED equivalents deliver comparable or better usable light at a fraction of the draw, and the saving compounds because these fixtures run every night, all night, roughly four thousand hours a year.

The second saving is maintenance. Metal halide lamps dim substantially over their life and then fail, and every replacement is a bucket truck, two people and a service call. A lot with twenty poles on an annual relamping cycle spends a meaningful sum each year simply keeping the old light on.

The third change is the quality of the light. LED is directional and controllable, so it can be aimed at the pavement rather than at the sky and the neighboring property. Converted lots usually end up with more even coverage and fewer dark patches between poles, even when total wattage falls sharply.

In most cases the existing poles, bases and underground circuits can be reused and only the fixture head is replaced, which is the difference between a straightforward project and a civil works one. We check the poles, the bases and the circuit before quoting, because reusing a corroded pole is a false economy.

Photometric Plans and Permits

A term most property owners meet for the first time when a plan reviewer asks for one.

A photometric plan is a drawing showing the calculated light levels across a site, point by point, produced from the specific fixtures proposed, their mounting heights and their aiming. Municipalities commonly require one before approving new or replacement site lighting, to confirm that the lot will be adequately lit, that light is not spilling onto neighboring properties or into the sky beyond what is permitted, and that the design meets whatever standards the code adopts.

Owners usually discover this mid-permit, having already chosen fixtures. We handle the photometric requirement as part of the project, so the fixture selection and the plan are developed together rather than the plan being produced to justify a choice already made.

It is also the right moment to get the design correct. A lot laid out from a photometric model has even coverage and no dark gaps, which is the outcome that matters when somebody asks later whether the property was adequately lit.

What South Florida Does to Exterior Lighting

Outdoor lighting here has a harder life than it does almost anywhere else, and fixture selection matters more than price.

Salt air corrodes everything. Near the ocean or the Intracoastal, housings, fasteners, gaskets and terminations corrode quickly, and failure usually starts inside where nobody is looking. Fixtures sold as suitable for coastal environments cost more and last several times longer, which on a pole requiring a bucket truck to reach is not a close decision.

Wind rating is not optional. Poles and fixtures have to be specified for the wind loads this county requires, and the fixture surface area contributes to the load on the pole. Putting a large fixture on a pole designed for a smaller one is a mistake that reveals itself in a storm.

Poles fail at the base. Water, salt and fertilizer attack the base and anchor bolts, and corrosion there is hidden by the base cover. A leaning pole is a late-stage symptom and should be treated as urgent.

Water gets everywhere. Driven rain finds failed gaskets, and underground circuits in wet ground find any splice that was not properly made. Most of the mysterious intermittent faults on parking lots trace back to a buried connection.

Lightning is frequent here, which is a reason to consider surge protection on site lighting circuits, particularly where the fixtures are LED with electronic drivers.

Decorative outdoor lighting fixture illuminating a commercial property exterior

When the Lot Goes Dark Tonight

Separate from any planned project. If poles are out now, that is a repair rather than a capital item and it should not wait for a budget cycle.

Common causes: a failed photocell leaving the circuit off, a tripped or failed contactor taking out a whole bank of poles, individual fixture or driver failures, a damaged underground circuit between poles, and storm damage. A whole lot going dark at once is usually a control or circuit problem rather than a fixture problem, which is good news, because it is faster and cheaper to fix.

We troubleshoot, locate underground faults, and carry out the repairs, including pole work.

24/7 emergency service: 561-582-2600

Why Property Managers Here Use Nassif Electric

  • Fifty years of commercial electrical work in South Florida, since 1976.
  • Florida statewide licensed unlimited electrical contractor, License EC13001410.
  • Licensed, insured and bonded, with documentation ready for property managers.
  • Fixtures specified for coastal conditions, because the cheap option fails first here.
  • Underground fault locating as well as fixture replacement.
  • Photometric plans handled as part of the permit process.
  • 24/7 response for dark lots and storm damage.
  • One contractor across lighting, distribution, generators and EV charging on the same property.

Areas We Serve

We handle commercial exterior lighting throughout West Palm Beach, including downtown, the Okeechobee Boulevard and Australian Avenue corridors and the surrounding retail and industrial properties, and across South Florida from Juno Beach to Fort Lauderdale: Palm Beach, Palm Beach Gardens, North Palm Beach, Jupiter, Riviera Beach, Lake Worth Beach, Greenacres, Wellington, Royal Palm Beach, Boynton Beach, Delray Beach and Boca Raton.

Frequently Asked Questions

  • Half our parking lot lights are out. What is usually wrong?

    If a whole bank went dark at once it is usually a control or circuit problem rather than the fixtures: a failed photocell, a tripped or failed contactor, or a damaged underground circuit. That is the better outcome, because it is faster and cheaper to put right than replacing fixtures. Individual lights out in scattered positions are usually fixture or driver failures. We troubleshoot before quoting rather than assuming.

  • Can you reuse our existing poles for an LED conversion?

    Usually yes, and that is what makes these projects affordable. In most conversions only the fixture head is replaced while the poles, bases and underground circuits stay. We inspect the poles and particularly the bases first, because corrosion at the base is common here and hidden by the base cover, and mounting new fixtures on a pole that is failing is a false economy.

  • How much will we save converting the lot to LED?

    It depends on what is installed now and how many fixtures there are, so the honest answer comes from counting them and reading the wattages. The reason the saving is usually large is that these fixtures run roughly four thousand hours a year, every year, and the old metal halide and high pressure sodium units draw several times what an LED equivalent does. Maintenance is the second saving: every lamp you do not replace is a bucket truck and two people you do not pay for.

  • What is a photometric plan and do we need one?

    It is a drawing showing calculated light levels across the site, point by point, based on the specific fixtures, mounting heights and aiming proposed. Municipalities commonly require one before approving new or replacement site lighting, to confirm the lot is adequately lit and that light is not spilling onto neighboring property or into the sky beyond what is allowed. Most owners find out about it mid-permit. We handle it as part of the project so the fixtures and the plan are developed together.

  • Do you have a bucket truck and do pole work?

    Yes. Pole-mounted work needs proper lift access, and doing it from a ladder is neither safe nor legal on most poles. We also set and replace poles and work on bases where that is what the job requires.

  • Our pole is leaning. Is that urgent?

    Yes, treat it as urgent. Leaning almost always means corrosion or damage at the base and anchor bolts, which in this climate is common and is hidden under the base cover until it is advanced. A leaning pole is a late-stage symptom rather than a cosmetic problem, and it should be assessed quickly.

  • Can you find a fault in the underground wiring between poles?

    Yes. Underground circuits in wet ground are a frequent cause of intermittent and partial lot failures, usually at a splice that was not properly made or at a cable damaged by later work. Locating the fault rather than digging the whole run is the useful part, and it is a specific skill.

  • What fixtures should we use this close to the ocean?

    Ones rated for coastal and marine environments, with appropriate housings, fasteners and gaskets. Standard fixtures corrode here, often from the inside where nobody sees it, and the failure arrives sooner than anyone expects. Given that replacing a fixture means a bucket truck and a crew, paying more up front for coastal-rated equipment is one of the easier decisions on this kind of project.

  • Can lighting reduce crime or our liability exposure?

    Good exterior lighting makes a property easier to use and to monitor, and insurers and tenants both pay attention to it. The important part is that it works by being even, aimed and properly controlled rather than by being bright. A badly placed floodlight creates glare and deep shadow beside it, which is worse than a lower, evenly distributed light level. We can advise on where the coverage is actually weak rather than simply adding wattage.

  • How quickly can you respond after a storm?

    We run 24/7 response, and after a named storm we prioritize existing clients and safety issues such as downed and leaning poles and exposed conductors. We also document damage for insurance purposes. The faults worth watching for are the ones that appear a week later, when water that got into a fixture or a splice finally causes a short.

  • Can you also handle the lighting inside the building?

    Yes. Interior commercial lighting, LED retrofits for offices, warehouses and retail space, high bay lighting and lighting controls are covered on our commercial LED retrofits page. Many properties do both at once, which is usually cheaper than doing them in separate years.

Get Your Site Lighting Assessed

We will walk the property after dark, show you where the coverage is actually weak, check the poles and bases, and quote the work. If the lot only needs a photocell and two fixtures, that is what we will tell you.

Call 561-582-2600 or email [email protected] for a site lighting assessment.

Electrical contractor reviewing building blueprints for commercial construction
Scroll to Top